El disco no responde a los comando de sg3 , y esto queda reflejado en el iostat aumentando el numero de errores de transporte:
root@seal:~# iostat -En|grep c2t5000CCA369C508E5d0
c2t5000CCA369C508E5d0 Soft Errors: 0 Hard Errors: 13 Transport Errors: 27
root@seal:~# sg_inq -u /dev/rdsk/c2t5000CCA369C508E5d0
inquiry: pass through os error: I/O error
inquiry: failed, res=-1
root@seal:~# sg_inq /dev/rdsk/c2t5000CCA369C508E5d0
SCSI INQUIRY failed on /dev/rdsk/c2t5000CCA369C508E5d0, res=-1
root@seal:~# iostat -En|grep c2t5000CCA369C508E5d0
c2t5000CCA369C508E5d0 Soft Errors: 0 Hard Errors: 13 Transport Errors: 29
Tampoco funciona el commando smartctl sobre este dispositivo:
root@seal:~# smartctl -a -d sat /dev/rdsk/c2t5000CCA369C508E5d0
smartctl 6.0 2012-10-10 r3643 [i386-pc-solaris2.11] (local build)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
Read Device Identity failed: I/O error
El zfs lo ha puesto en "desconfigurado"
root@seal:~# cfgadm -av c9
Ap_Id Receptacle Occupant Condition Information
When Type Busy Phys_Id
c9 connected configured unknown
unavailable scsi-sas n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi
c9::es/ses2 connected configured unknown LSI CORP SAS2X36
unavailable ESI n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::es/ses2
c9::smp/expd2 connected configured unknown LSI CORP SAS2X36
unavailable smp n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::smp/expd2
c9::w5e83a972b7f39c50,0 connected configured unknown Client Device: /dev/dsk/c2t5E83A972B7F39C50d0s0(sd58)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5e83a972b7f39c50,0
c9::w5000cca369c4e90b,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C4E90Bd0s0(sd73)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c4e90b,0
c9::w5000cca369c4f888,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C4F888d0s0(sd66)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c4f888,0
c9::w5000cca369c50f1f,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C50F1Fd0s0(sd79)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c50f1f,0
c9::w5000cca369c504d1,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C504D1d0s0(sd61)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c504d1,0
c9::w5000cca369c505d5,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C505D5d0s0(sd64)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c505d5,0
c9::w5000cca369c506af,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C506AFd0s0(sd80)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c506af,0
c9::w5000cca369c506bb,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C506BBd0s0(sd72)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c506bb,0
c9::w5000cca369c508c9,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C508C9d0s0(sd67)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c508c9,0
c9::w5000cca369c508e0,0 connected configured unknown Client Device: /dev/dsk/c2t5000CCA369C508E0d0s0(sd35)
unavailable disk-path n /devices/pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0:scsi::w5000cca369c508e0,0
c9::w5000cca369c508e5,0 connected unconfigured unknown Client Device: /dev/dsk/c2t5000CCA369C508E5d0s0(sd63)
El fallo se produjo el dia 28:
root@seal:~# fmdump -m -u 9cd1792d-ff03-ce0c-aad0-be392c7f2c9a
SUNW-MSG-ID: ZFS-8000-FD, TYPE: Fault, VER: 1, SEVERITY: Major
EVENT-TIME: Thu Mar 28 11:08:16 CET 2013
PLATFORM: X8DTH-i-6-iF-6F, CSN: 1234567890, HOSTNAME: seal
SOURCE: zfs-diagnosis, REV: 1.0
EVENT-ID: 9cd1792d-ff03-ce0c-aad0-be392c7f2c9a
DESC: The number of I/O errors associated with a ZFS device exceeded
acceptable levels. Refer to http://illumos.org/msg/ZFS-8000-FD for more information.
AUTO-RESPONSE: The device has been offlined and marked as faulted. An attempt
will be made to activate a hot spare if available.
IMPACT: Fault tolerance of the pool may be compromised.
REC-ACTION: Run 'zpool status -x' and replace the bad device.