Opened 9 years ago
Last modified 9 years ago
#236 assigned defect
fallo en c2t5000CCA369C509D4d0
Reported by: | fernando | Owned by: | fernando |
---|---|---|---|
Priority: | major | Milestone: | |
Component: | TracMeteo | Keywords: | |
Cc: |
Description (last modified by fernando)
- c2t5000CCA369C509D4d0 FAULTED 0 32 0 too many errors
- iostat -exn c2t5000CCA369C509D4d0: 0.1 3.6 2.2 76.3 0.0 0.0 0.0 1.2 0 0 2 0 6 8 c2t5000CCA369C509D4d0
admin@seal:~$ iostat -Ex c2t5000CCA369C509D4d0 extended device statistics device r/s w/s kr/s kw/s wait actv svc_t %w %b sd175 0.1 3.6 2.2 76.2 0.0 0.0 1.2 0 0 sd175 Soft Errors: 2 Hard Errors: 0 Transport Errors: 6 Vendor: ATA Product: Hitachi HDS72302 Revision: A580 Serial No: MN3220F30B2LHE Size: 2000.40GB <2000398934016 bytes> Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 2 Illegal Request: 0 Predictive Failure Analysis: 0
fmdump -m -u 02b085b1-7953-4554-c4b1-f1302bcff05d SUNW-MSG-ID: ZFS-8000-FD, TYPE: Fault, VER: 1, SEVERITY: Major EVENT-TIME: Sat May 18 06:44:46 CEST 2013 PLATFORM: X8DTH-i-6-iF-6F, CSN: 1234567890, HOSTNAME: seal SOURCE: zfs-diagnosis, REV: 1.0 EVENT-ID: 02b085b1-7953-4554-c4b1-f1302bcff05d DESC: The number of I/O errors associated with a ZFS device exceeded acceptable levels. Refer to http://illumos.org/msg/ZFS-8000-FD for more information. AUTO-RESPONSE: The device has been offlined and marked as faulted. An attempt will be made to activate a hot spare if available. IMPACT: Fault tolerance of the pool may be compromised. REC-ACTION: Run 'zpool status -x' and replace the bad device.
Señalizar y deseñalizar:
root@seal:~/LSIUTIL/sg3_utils-1.34/src# sg_ses -I 0,0 --set=fault /dev/es/ses2 root@seal:~/LSIUTIL/sg3_utils-1.34/src# sg_ses -I 0,0 --clear=fault /dev/es/ses2
Reemplazo:
log al meter el nuevo disco: Jun 11 16:50:27 seal genunix: [ID 483743 kern.info] /scsi_vhci/disk@g5000cca369c508e5 (sd63) multipath status: degraded: path 7 mpt_sas4/disk@w5000cca369c508e5,0 is online zpool replace depot c2t5000CCA369C509D4d0 c2t5000CCA369C508E5d0 sudo zpool detach depot c2t5000CCA369C509D4d0
Change History (5)
comment:1 Changed 9 years ago by fernando
- Description modified (diff)
- Owner set to fernando
- Status changed from new to assigned
comment:2 Changed 9 years ago by fernando
comment:3 Changed 9 years ago by fernando
- Description modified (diff)
comment:4 Changed 9 years ago by fernando
En este caso utilizo los números de serie que hay en https://www.meteo.unican.es/trac/meteo/wiki/Jbods
o bien directamente con el dispositivo "LETRAS en minúscula" /device/SCSI_vhci/disk@g.........
y mirando el "attached-port" value='w5003048001155a7f'
prtconf -Dcv /devices/scsi_vhci/disk@g5000cca369c509d4 root@seal:~/LSIUTIL/sg3_utils-1.34/src# prtconf -v|grep -B6 -A310 F30B2LHE|more disk, instance #175 System software properties: name='ddi-devid-registrant' type=int items=1 value=00000001 Driver properties: name='inquiry-serial-no' type=string items=1 dev=none value='MN3220F30B2LHE' name='pm-components' type=string items=3 dev=none value='NAME=spindle-motor' + '0=off' + '1=on' name='pm-hardware-state' type=string items=1 dev=none value='needs-suspend-resume' name='ddi-failfast-supported' type=boolean dev=none name='ddi-kernel-ioctl' type=boolean dev=none name='fm-ereport-capable' type=boolean dev=none name='device-nblocks' type=int64 items=1 dev=none value=00000000e8e088b0 name='device-blksize' type=int items=1 dev=none value=00000200 Hardware properties: name='devid' type=string items=1 value='id1,sd@n5000cca369c509d4' name='class' type=string items=1 value='scsi' name='inquiry-revision-id' type=string items=1 value='A580' name='inquiry-product-id' type=string items=1 value='Hitachi HDS72302' name='inquiry-vendor-id' type=string items=1 value='ATA' name='inquiry-device-type' type=int items=1 value=00000000 name='pm-capable' type=int items=1 value=00000001 name='compatible' type=string items=4 value='scsiclass,00.vATA.pHitachi_HDS72302.rA580' + 'scsiclass,00.vATA.pHitachi_HDS72302' + 'sc siclass,00' + 'scsiclass' name='client-guid' type=string items=1 value='5000cca369c509d4' Paths from multipath bus adapters: Path 136: /pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0/disk@w5000cca369c509d4,0 mpt_sas#4 (offline) name='wwn' type=string items=1 value='5000cca369c509d4' name='lun' type=int items=1 value=00000000 name='lun64' type=int64 items=1 value=0000000000000000 name='target-port' type=string items=1 value='w5000cca369c509d4' name='attached-port' type=string items=1 value='w5003048001155a7f' name='obp-path' type=string items=1 value='/pci@7a,0/pci8086,340e@7/pci1000,3080@0/disk@w5000cca369c509d4,0' name='phy-num' type=int items=1 value=0000000c name='path-class' type=string items=1 value='primary' Device Minor Nodes: dev=(269,11200) dev_path=/scsi_vhci/disk@g5000cca369c509d4:a spectype=blk type=minor dev_link=/dev/dsk/c2t5000CCA369C509D4d0s0 dev_path=/scsi_vhci/disk@g5000cca369c509d4:a,raw spectype=chr type=minor dev_link=/dev/rdsk/c2t5000CCA369C509D4d0s0 Device Minor Layered Under: mod=zfs accesstype=blk dev_path=/pseudo/zfs@0
comment:5 Changed 9 years ago by fernando
- Description modified (diff)
En este caso utilizo los números de serie que hay en https://www.meteo.unican.es/trac/meteo/wiki/Jbods
o bien directamente con el dispositivo "LETRAS en minúscula" /device/SCSI_vhci/disk@g.........
y mirando el "attached-port" value='w5003048001155a7f'
prtconf -Dcv /devices/scsi_vhci/disk@g5000cca369c509d4 root@seal:~/LSIUTIL/sg3_utils-1.34/src# prtconf -v|grep -B6 -A310 F30B2LHE|more disk, instance #175 System software properties: name='ddi-devid-registrant' type=int items=1 value=00000001 Driver properties: name='inquiry-serial-no' type=string items=1 dev=none value='MN3220F30B2LHE' name='pm-components' type=string items=3 dev=none value='NAME=spindle-motor' + '0=off' + '1=on' name='pm-hardware-state' type=string items=1 dev=none value='needs-suspend-resume' name='ddi-failfast-supported' type=boolean dev=none name='ddi-kernel-ioctl' type=boolean dev=none name='fm-ereport-capable' type=boolean dev=none name='device-nblocks' type=int64 items=1 dev=none value=00000000e8e088b0 name='device-blksize' type=int items=1 dev=none value=00000200 Hardware properties: name='devid' type=string items=1 value='id1,sd@n5000cca369c509d4' name='class' type=string items=1 value='scsi' name='inquiry-revision-id' type=string items=1 value='A580' name='inquiry-product-id' type=string items=1 value='Hitachi HDS72302' name='inquiry-vendor-id' type=string items=1 value='ATA' name='inquiry-device-type' type=int items=1 value=00000000 name='pm-capable' type=int items=1 value=00000001 name='compatible' type=string items=4 value='scsiclass,00.vATA.pHitachi_HDS72302.rA580' + 'scsiclass,00.vATA.pHitachi_HDS72302' + 'sc siclass,00' + 'scsiclass' name='client-guid' type=string items=1 value='5000cca369c509d4' Paths from multipath bus adapters: Path 136: /pci@7a,0/pci8086,340e@7/pci1000,3080@0/iport@f0/disk@w5000cca369c509d4,0 mpt_sas#4 (offline) name='wwn' type=string items=1 value='5000cca369c509d4' name='lun' type=int items=1 value=00000000 name='lun64' type=int64 items=1 value=0000000000000000 name='target-port' type=string items=1 value='w5000cca369c509d4' name='attached-port' type=string items=1 value='w5003048001155a7f' name='obp-path' type=string items=1 value='/pci@7a,0/pci8086,340e@7/pci1000,3080@0/disk@w5000cca369c509d4,0' name='phy-num' type=int items=1 value=0000000c name='path-class' type=string items=1 value='primary' Device Minor Nodes: dev=(269,11200) dev_path=/scsi_vhci/disk@g5000cca369c509d4:a spectype=blk type=minor dev_link=/dev/dsk/c2t5000CCA369C509D4d0s0 dev_path=/scsi_vhci/disk@g5000cca369c509d4:a,raw spectype=chr type=minor dev_link=/dev/rdsk/c2t5000CCA369C509D4d0s0 Device Minor Layered Under: mod=zfs accesstype=blk dev_path=/pseudo/zfs@0
Note: See
TracTickets for help on using
tickets.
El sistema lo marca como unconfigured, por lo que no funciona la herramienta sg_inq ni la herramienta smarctl dan "I/O error"